ELEVATOR INTELLIGENCE BUILT FOR THE FIELD

VERTICAL
INTELLIGENCE™

Deterministic control. Recorded evidence. Advisory intelligence.

A modular elevator platform for Brake, Door Lock Monitoring, and UCM / Rope-Gripper applications.

VI turns real equipment signals into validated states, deterministic decisions, event history, and technician-readable diagnostics—while keeping AI outside the control path.

THE VI CONTROL + DIAGNOSTIC MODEL
SENSEField inputs and equipment stateVALIDATEDeterministic state and timingDECIDE + ACTDefined PLC control / protective outputsVERIFY + RECORDFeedback, sequence, fault historyEXPLAINTechnician-facing advisory intelligence

AI explains the evidence. The PLC owns deterministic control.

THE ARCHITECTURE

Control and intelligence are intentionally separated.

Field

Signals & feedback

→
VI PLC

Validate · Decide · Act

→
History

Verify · Record

→
HMI

Status · Faults · Requests

→
VI Assistant

Explain · Guide

Deterministic PLC layer
May operate defined control, inhibit, permissive, or protective-interface outputs according to the validated implementation.
Advisory AI layer
May explain faults and suggest verification steps. It does not command movement, force outputs, reset protective logic, or declare equipment safe to return to service.
TECHNICIAN-CENTERED

A fault code should start the diagnosis—not end it.

VI records what happened and preserves the sequence around it.

BRK-Fxxx and DLM-Fxxx are public mechanic-facing codes. Internal PLC addresses remain engineering references. The diagnostic method is: Observe → Validate → Correlate → Diagnose → Guide.

See the Diagnostic Workflow
EVENTDLM-F013
OBSERVATION

Gate remained made at DOL break during reopening.

VI PRINCIPLE

Do not condemn a component from the code alone. Reconstruct the sequence and verify field evidence.

INTERACTIVE VI SYSTEM VIEW

See how VI turns signals into technician evidence.

This demonstration is illustrative and does not connect to or command elevator equipment. Select a scenario to follow the diagnostic path.

VERTICAL INTELLIGENCE™ / LIVE DEMO
MONITORING
COMMAND / COILON
SW1 / GATEPROVED
SW2 / INTERLOCKPROVED
TECHNICIAN EVENTSystem normal — evidence being recorded.

VI is validating field feedback and preserving the event sequence.

DIAGNOSTIC PATH

Normal monitored cycle

1
OBSERVE

Field signals agree with the monitored state.

2
VALIDATE

PLC validates the expected deterministic sequence.

3
RECORD

Timing and state evidence remain available for history.

4
EXPLAIN

The VI Assistant can explain recorded evidence; it does not actuate equipment.

PLCDeterministic control authority
HMIStatus, history & technician requests
HISTORYSequence & timing evidence
AIAdvisory explanation only
PRODUCT DISCIPLINE

Current. Development. Roadmap.

VI separates released/current implementation from development work and future concepts. Control capability does not itself establish certification, listing, code compliance, or jurisdictional acceptance.

CURRENT

Implemented architecture

Brake, DLM and combined Brake/UCM PLC projects; HMI/fault-history workflow; technician diagnostic language.

DEVELOPMENT

Product refinement

Controlled-document reconciliation, commissioning procedures, hardware integration and validation.

ROADMAP

Expanded intelligence

Future capabilities are labeled as roadmap until validated and released.